Ducab RuBICC – H07RN-F Rubber Flexibles are designed to provide excellent flexibility during Click here to download Ducab RuBICC – H07RN-F brochure. details on lead sheath cables refer our lead sheath power, control and auxilary cable catalogue). (g). (1) XLPE insulation Ultra-violet (UV) colour masterbatch. Established in , Ducab is the leading cable manufacturing company in the This catalogue provides working information on PVC insulated wiring cables.

Author: Grolmaran Kazirisar
Country: Chile
Language: English (Spanish)
Genre: Photos
Published (Last): 11 May 2015
Pages: 296
PDF File Size: 12.94 Mb
ePub File Size: 16.42 Mb
ISBN: 647-8-67289-733-9
Downloads: 47868
Price: Free* [*Free Regsitration Required]
Uploader: Melkis

Ducab has set improvement targets to reduce the significant environmental impacts associated with its activities. Rating factors to take account of variations in ground temperatures are given in Table 2. Again the area required cataloghe on the characteristics of the device providing protection against short circuit.

Wherever possible larger installation radii should be used. Blue, Brown, Black, Grey could also be supplied on special request FILLERS For providing circular shape to the cable, ducav compatible fillers wherever necessary are included between laid up cores.

Much more time is available to enable the orderly evacuation of people from buildings when a fire is discovered. Besides the time needed for people to evacuate a building, extra time is essential to the emergency services personnel who have to enter the building to control and extinguish the fire and assist those needing help.

LSZH cables should be used in any location where the outbreak of fire would constitute an immediate threat to life and to the performance of sensitive electronic equipment. It should also be ensured that the cable size ultimately selected is capable of carrying the required current under site conditions of installation.

Ducab RuBICC – H07RN-F

Refer to Table 16, 32 and 34 for single core cable armour wire diameter Notes: For details on LSZH cables refer page e In water logged areas or where the cables are required to be abrasion resistant, cable with medium density polyethylene MDPE can be offered. However single end bonding results in an induced voltage at the unearthed end of the armour. For 2 core cables, 50 mm2 and above have D-shaped conductors.

For any given run the values need to be multiplied by the length of the vatalogue in metres and by the current in amperes that the cables are to carry.

  APR9600 DATASHEET PDF

Smoke diminishes the time available by reducing visibility, hindering mobility and causing bodily harm. They also attack the electronic circuitry of sophisticated equipment used in modern offices causing costly damage. Ducab has made a major contribution to meeting these requirements, with the development of a range of Ducab Smokemaster Low Smoke Zero Halogen armoured power and wiring cables.

At standard defined conditions: To meet the growing demand of customers around the region and the world, Ducab continues to expand its world-class facilities across the Middle Cahalogue, North Africa, Europe and India.

To use the application click here. TYPE Single and Multi-Core Flexible Cables USE Designed for indoor wiring applications, connecting handheld equipments such as power drills, hand grinders etc where cables are subjected to stress by kinking and twisting.

Ducab is particularly proud to have achieved certification to the stringent ISO standard as it is an independent conformation that the company designs, manufactures and tests cables consistently to accepted standards. Ducab Smokemaster cables provide improved fire protection and reduce the risk to building occupants. Values of voltage drop are tabulated for a current of one ampere for a 1 metre run, i.

For balanced three phase ac circuits, the values dhcab to the line voltage. Direct in ground – Cables touching Single way ducts – ducts touching Note: Jointing and terminating of XLPE insulated cables does not require any special techniques.

The details on this are provided on request. For detailed product description and characteristics, reference can be made to the respective FlamBICC product data in this catalog. Catalpgue is especially important where aluminium wire armour is used, as ingress of moisture could lead to corrosion or ultimate loss of earth continuity. Derating factor for this temp.

Higher insulation strength and superior mechanical properties allow lower insulation thickness. These are screened cables designed as per BS and are mainly used in fire detection, voice alarm, emergency lighting etc.

DUCAB Fire Performance Cables

Designed for indoor wiring applications, connecting handheld equipments such as power drills, hand grinders etc where cables are subjected to stress by kinking and twisting.

Any other special requirement, e. All the cables described in this publication can be used indoors or outdoors, but some reservations are necessary concerning cables for direct burial in the ground or for use in sustained wet conditions as follows: Ducab Smokemaster does not produce acid gas.

  JACQUES RIGAUT PDF

The cable must be free from material and manufacturing defects, and weaknesses that will be revealed in service. Density of XLPE is 0.

XLPE Insulated Low Voltage Cables

Fire Performance Cables are intended for applications requiring circuit integrity during fire. It will be seen that this value is 0.

These essential structural features form natural draught corridors which spread the problem of smoke and fumes to areas of dcab building which may not be affected by the fire itself — putting people at risk. Based on the structure of OHSASthe standard requires cayalogue improvement in health and safety related activities. NOTE – They can be customized as per customer specific requirement with options for sheathing materials and armour types.

The recommendations catalogus are given in good faith but Ducab cannot be held liable for mistakes in selection however caused. Alternatively the most appropriate group rating factor must be applied when determining the cable size and required number of cables in parallel.

Andy Lehrens presentation on Wikileaks. Duflex – Ducab Flexible Cables. Material Galvanised round steel wire GSW.

Ducab Records Growth for OGP Business with Three Major Contracts

Rating factors to take account of variation in ground temperatures are given in Table 2. Where the phase angles of the loads fall catalovue this range, the voltage drop deduced from the tables may be unduly conservative and more exact methods of calculation should be employed.

Not to be used for promotional or job application purposes! When ordering connectors specify stud hole size required. It should also be ensured that the cable size ultimately selected is capable of carrying the required current under the site conditions of installation. During F fire test direct mechanical impact and water jet is provided on the cable during fire test.